User Manual Facility Performance Testing 7-
4. Verify that the central computer
correctly logged this alarm and that any
networked computer also sees the alarm.
5. Record the results (pass or fail).
6. If the test fails to cause a Band Alarm:
a. Notify staff and security of the
vulnerable area.
b. Check for visible damage or
tampering to the zone equipment.
c. Have a maintenance technician
verify power to the zone equipment
d. Call your Accutech Representative.
7. To clear the alarm, deactivate the BR42
test Tag, enter a Keypad reset and, if
necessary, clear the alarm on the PC.