Wave Guide
Wave Guide
DANGER
All High Voltage Capacitors must be discharged before performing this procedure.
The Wave Guide channels the microwaves generated by the Magnetron into the cooking chamber.
Removal and Replacement
1. Disconnect oven from Power Supply.
2. Remove Top, Right, Left and Rear Panels
(see Panel Removal).
3. Discharge HV Capacitors.
4. Remove Rear Exhaust Duct
(see Rear Exhaust Duct Removal).
5. Remove Magnetron (see Magnetron Removal).
6. Remove Stirrer Motor (see Stirrer Motor Removal).
7. Remove the Stirrer Motor Mounting bracket by removing
four (4) 11/32” (9mm) Hex Nuts. Lift up and out.
8. Remove 11/32” (9mm) Hex Nuts on each side of Wave
Guide.
9. Inside the oven, remove the Top Forced Air Plate by
removing four (4) Phillips Head Screws in each corner.
10. Loosen, but do not remove, four (4) Phillips Head
Screws securing the toggles securing the Microwave
Window. Gently pry the Microwave Window down to
release the Foam Gasket.
11. Remove the Antenna Gear by rst removing the oblong
Keeper, then pressing rmly on the Split Shaft with a
1/4” Socket. Lift Gear up and o󰀨.
12. From inside the oven chamber, remove the four (4)
1/4” Hex Nuts from around the Antenna.
13. Pull the Antenna down and remove.
14. To replace, reverse these steps.