4-10
4.1 Overview SPM-32A ... SPM-36A
• After the key sequence [*], [dBm0]
(="REL(dBr)") has been entered,
the stored reference level can be
incremented or decremented by
1 dBr or 0.1 dB.
• [DEMOD]: increases or decreases
the volume in steps of 6 dB (or 2dB)
• [MEM]: the address number is
increased or decreased by 5 or 1.
"RCL MEM": for recalling setups. The
address which was last set is displayed
initially. The address number can then be
entered (0 to 99), or altered with the up /
down keys; the entry is terminated with
[ENTER8].
"STO MEM":stores the current setup and
result at an address between 0 and 99
(see RCL MEM).
"DISPLAY MEM": displays a setup that
has been stored. The last value that was
measured before the setup was stored is
also displayed. It is not possible to make
measurements when the setup is being
displayed. The display is cleared by
pressing [*], [
↓↓
] or any key in the FREQ
or MODE groups.
For more on addresses
see "RCL MEM".
"MEM OFF": Cancels the memory mode,
addresses are no longer displayed.
*
RCL MEM
*
STO MEM
*
DISPLAY MEM
*
MEM OFF