SPM-32A ... SPM-36A 4.2 Operation and features
4-25
Voltage levels and power levels
Voltage levels (dB) are referred to a voltage of 0.775 V
(1 mW into 600 ). For this reason, the level does not
change when measurements are made using a generator
with an output impedance of 0 and various input
impedances are selected.
Power levels (dBm) are referred to 1mW. When a different
input impedance is selected a different level will be displayed
by the instrument.
Table 4-2 Power levels for 0.775 V into Z
in
Table 4-3 Voltage for 0 dBm into Z
in
(P = 1 mW)
Z/ 50 75 124 135 140 150 600
L
p
/dBm 10.89.036.856.486.326.020
Z/
50 75 124 135 140 150 600
V
z
/V
0.223 0.274 0.352 0.367 0.374 0.387 0.775