Installation and Commissioning Guide
Split Ducted Units
PRELIMINARY DATA ONLY Ver. 3.03 220620
THIS LABEL TO BE REMOVED ON SIGN-OFF
11
Installation and Commissioning Guide - Split Ducted Indoor Unit
Doc. No.0525-084 Ver. 3 22xxxx
UNIT MODEL NUMBER
UNIT WEIGHT
(kg)
EAA210S 40
EAA240S 43
SIDE VIEW
21
1368
21
410
61
486 O/A
158 1094
165
160
11
11
342 O/A
13
28
302
360
87
22
131
69
89
238
360
22
18
30
39
153
410
61
1581094158
SAFETY DRAIN
Ø 25mm ID
PRIMARY DRAIN
Ø 25mm ID
COIL SENSOR HOLE
Ø 25mm
158
1410 A/O
1346
GAS PIPE
Ø 25.4mm (1")
SWAGED
LIQUID PIPE
Ø 12.7mm (1/2")
SWAGED
41
TOP VIEW
EAA210S  EAA240S
OVERALL NOMINAL DIMENSION H X W X D
= 486 X 1410 X 342
SUPPLY DUCT H X W = 410 X 1094
RETURN DUCT = 410 X 1094
FRONT VIEW - SUPPLY AIR
21
1368
21
410
61
486 O/A
158 1094
165
160
11
11
342 O/A
13
28
302
360
87
22
131
69
89
238
360
22
18
30
39
153
410
61
1581094158
SAFETY DRAIN
Ø 25mm ID
PRIMARY DRAIN
Ø 25mm ID
COIL SENSOR HOLE
Ø 25mm
158
1410 A/O
1346
GAS PIPE
Ø 25.4mm (1")
SWAGED
LIQUID PIPE
Ø 12.7mm (1/2")
SWAGED
41
REAR VIEW - RETURN AIR
21
1368
21
410
61
486 O/A
158 1094
165
160
11
11
342 O/A
13
28
302
360
87
22
131
69
89
238
360
22
18
30
39
153
410
61
1581094158
SAFETY DRAIN
Ø 25mm ID
PRIMARY DRAIN
Ø 25mm ID
COIL SENSOR HOLE
Ø 25mm
158
1410 A/O
1346
GAS PIPE
Ø 25.4mm (1")
SWAGED
LIQUID PIPE
Ø 12.7mm (1/2")
SWAGED
41
21
1368
21
410
61
486 O/A
158 1094
165
160
11
11
342 O/A
13
28
302
360
87
22
131
69
89
238
360
22
18
30
39
153
410
61
1581094158
SAFETY DRAIN
Ø 25mm ID
PRIMARY DRAIN
Ø 25mm ID
COIL SENSOR HOLE
Ø 25mm
158
1410 A/O
1346
GAS PIPE
Ø 25.4mm (1")
SWAGED
LIQUID PIPE
Ø 12.7mm (1/2")
SWAGED
41
MINIMUM SERVICE ACCESS AREAS AND AIRFLOW CLEARANCES
TOP VIEW
HEIGHT CLEARANCE = 410mm
DUCT WORK
DUCT WORK
TO FAN SECTION
0M MIN  6M MAX
*RIGHT
SERVICE
CLEARANCE
890 MM
COIL SECTION
LEFT
SERVICE
CLEARANCE
890 MM
* Electrical box and/or
pipe connections are
located on the Right
side of the indoor unit.
NOTES:
1. Do not scale drawing. All dimensions are in mm unless specified.
2. Service Clearances given are suggested minimum based on the condition that the spaces around the units
are free from any obstructions and a walkway passage of 1000mm between the units or between the unit and the outside
perimeter is available.
3. Minimum service access clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges
incurred due to lack of access.
Left Service Clearance can be 100mm minimum if Right Service Clearance is applicable.
Right Service Clearance can be 600mm minimum if Left Service Clearance is applicable.
Height Service Clearance can be 100mm minimum if Right Service Clearance is applicable.
THIRD ANGLE
PROJECTION