EasyManuals Logo

Ada Delta-88 User Manual

Default Icon
139 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
26
Delta-88 Main AC Connections (cont.)
Option 8 - One Delta-88 at MainFrame, One PCT-8 Remotely Located, No ACC-3000
Some system layouts will base the Delta-88(s) in a utility
closet or basement while the sources are located at some
distance from the mainframe. When several sources are
grouped in a remote location together, it will be benefi-
cial to situate the PCT-8 with the sources. This does not
pose a problem but you will need to run an ADA Bus™
cable, a two conductor low voltage wire for turning the
PCT-8 on/off with the system, and addi-
tional low voltage wires to turn the sources
on and off (remote source AC switching
should be done using ACC-3000 or ACC-3
discussed in the up coming sections). When
just focusing on the PCT-8, it is important to
remember that it will need to be switched on
and off with the Delta-88 in order to re-boot
the system. You will therefore need an ACC-3 Low Voltage Controlled AC Outlet which can
cut power to the PCT-8 when the Delta-88 is turned off. Since it is easier to run long low voltage
cables than high voltage cables, a simple two conductor wire can be used to trigger the ACC-
3 (and in turn the PCT-8) from a 3-24 Volt AC or DC transformer (the ACC-3 accepts a wide
range input trigger) plugged into the Delta-88's Switched AC Outlet. When using several
Delta-88's, this transformer would plug into the last Delta-88 or an available outlet on an RPS-
1. When connecting to a Delta-88's Switched AC outlet, you will need to use a special male EIC
to female standard AC connector.
Option 9 - One Delta-88 at MainFrame, One PCT-8 & ACC-3000 Remotely Located
In this example, the ACC-3000 is included for source
AC switching, and as in the above option, can be
located along with the PCT-8 and source equip-
ment. However, unlike previous options using an
ACC-3000 (where the ACC-3000's power switch
provided the master reset), the master reset switch
in a remote source scenario goes back to the main
Delta-88's Main Power Switch. Again, as in the
previous option, an ACC-3 is used to provide
switched AC power the ACC-3000. The PCT-8 is
plugged into the ACC-3000's Switched "B" outlet
which will allow you to reset only the PCT-8 from
the source location as this sometimes is
helpful while programming the PCT-8.
Usually, the ACC-3000's power switch will
always be left on. Again, since program-
ming the system is done from the primary
Delta-88, the switch which re-boots the
system should also be on the Delta-88.
1234
ACC-3000
FUSE
AC POWER
SWITCHED B
SWITCHED A
8
7
6
5
4
3
2
1
ADA BUS
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
1
2
3
4
5
6
7
8
AUDIO
INPUTS
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
432121
ADA BUS™
MUTE L.V.
ZONE L.V.
OUT
AC INPUT
AC
LOOP OUT
TO DELTA-88
1
2
1
2
3 4
34
5 6
56
7
8
7
8
VSM-8
VIDEO SWITCHER
V
I
D
E
O
I
N
P
U
T
V
I
D
E
O
O
U
T
P
U
T
Standard
EIC Female
To Male AC
Connector
Standard
EIC Female
To Male AC
Connector
Standard EIC Female
To Male AC Connector
Special
EIC Female
To Female
AC Connector
1234
PCT-8
FUSE
AC POWER
ADA BUS
115 V
VOLTAGE
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
1
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
2
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
3
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
4
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
5
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
6
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
7
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
8
DATADATADATADATADATADATADATADATA
PCT-8 Located Away From the Delta-88
ACC-3000 & PCT-8 are Together
Main Delta-88
12V
DC
ACC-3
1234
-A+ -B+
12 VDC
X-Former
2 Cond. Low
Voltage Wire
ACC-3
PCT-8 Plugged Into
the ACC-3000's
Switched "B"
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
1
2
3
4
5
6
7
8
AUDIO
INPUTS
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
432121
ADA BUS™
MUTE L.V.
ZONE L.V.
OUT
AC INPUT
AC
LOOP OUT
TO DELTA-88
1
2
1
2
3 4
34
5 6
56
7
8
7
8
VSM-8
VIDEO SWITCHER
V
I
D
E
O
I
N
P
U
T
V
I
D
E
O
O
U
T
P
U
T
Standard
EIC Female
To Male AC
Connector
Standard
EIC Female
To Male AC
Connector
Special
EIC Female
To Female
AC Connector
1234
PCT-8
FUSE
AC POWER
ADA BUS
115 V
VOLTAGE
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
1
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
2
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
3
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
4
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
5
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
6
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
7
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
8
DATADATADATADATADATADATADATADATA
PCT-8 Located Away From the Delta-88
Main Delta-88
12V
DC
ACC-3
1234
-A+ -B+
12 VDC
X-Former
2 Cond. Low
Voltage Wire
ACC-3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ada Delta-88 and is the answer not in the manual?

Ada Delta-88 Specifications

General IconGeneral
BrandAda
ModelDelta-88
CategoryStereo System
LanguageEnglish

Related product manuals