Delta-88 Main AC Connections (cont.)
Option 6 - One Delta-88, One PCT-8, & One ACC-3000
When using the PCT-8 and an ACC-3000, the Delta-88 need no longer have its Main Power
Switch act as the re-boot switch. The ACC-3000 also has a power switch and will be better
suited to provide the master AC
switching. While the ACC-3000
also switches sources on and off as
needed, it also has two additional
switched AC outlets marked "A"
and "B". When wiring the system's
AC Bus, the Delta-88 should be
plugged into the ACC-3000's
Switched "B" AC outlet. Again, as
in previous pages, the PCT-8 can
plug into the Delta-88. When the
ACC-3000's power switch is turned
off, the Delta-88 and PCT-8 will
also turn off. When the ACC-3000
is turned on, the entire system will
re-boot. Please note, if the special
EIC AC line cord for the PCT-8 to Delta-88 connection was not included with your system, you
can connect both the PCT-8 and Delta-88 to the ACC-3000's Switched "B" AC outlet using a AC
power strip.
Using ACC-48s for both source
and amplifier AC switching.
The Delta-88 features a second 9-Pin D Connec-
tor on the upper right hand corner of the back of
the Delta-88. This connector will only track
zones, providing a low voltage output for zones
that are on. As such, it can be used to engage AC
for components such as zone specific external
power amplifiers or home theater systems. Us-
ing this connector permits you to use the 9-Pin D
connector on the Delta back's left side for sources
(with ACC-48(s)).
You can also use the zone tracking 9-Pin D con-
nector (upper right hand side of the Delta-88s
back) with a DB-9 and ACC-3. Using this combination
permits you to utilize the 15Amp rated ACC-3 for
amplifier on/off vs. the 10Amp rated ACC-48. You
can also more easily locate amplifiers away from the
main frame as the ACC-3 uses a low voltage two wire
trigger vs. a ribbon cable.
1234
ACC-3000
FUSE
AC POWER
SWITCHED B
SWITCHED A
8
7
6
5
4
3
2
1
ADA BUS
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
1
2
3
4
5
6
7
8
AUDIO
INPUTS
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
432121
ADA BUS™
MUTE L.V.
ZONE L.V.
OUT
AC INPUT
AC
LOOP OUT
TO DELTA-88
1
2
1
2
3 4
34
5 6
56
7
8
7
8
VSM-8
VIDEO SWITCHER
V
I
D
E
O
I
N
P
U
T
V
I
D
E
O
O
U
T
P
U
T
Standard
EIC Female
To Male AC
Connector
Special
EIC Female
To EIC Male
AC Connector
1234
PCT-8
FUSE
AC POWER
ADA BUS
115 V
VOLTAGE
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
1
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
2
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
3
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
4
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
5
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
6
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
7
CARRIER
DATA
CARRIER
LEVEL
5VDC
PULSE
INPUT
8
DATADATADATADATADATADATADATADATA
PCT-8
ACC-3000 Acts As Main Power Switch
Delta-88
To AC Circuit
To ACC-3000 Switched "B"
12345678
TO 9 PIN "D"
DELTA-88123456781234567812345678
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1. Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2. Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3421
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
1
2
3
4
5
6
7
8
AUDIO
INPUTS
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
FIX
VAR
SPEAKER
LR
+
-
LINE
RAM-50
432121
ADA BUS“
MUTE L.V.
SOURCE
L.V.
OUT
AC INPUT
AC 
LOOP OUT
TO DELTA-88
1
2
1
2
3 4
34
5 6
56
7
8
7
8
VSM-8
VIDEO SWITCHER
V
I
D
E
O
I
N
P
U
T
V
I
D
E
O
O
U
T
P
U
T
ZONE 
L.V. OUT
AC OUTLETS FOR 
DECODER & AMP
12345678
TO 9 PIN "D"
DELTA-88123456781234567812345678
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1. Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2. Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3421
12345678
TO 9 PIN "D"
DELTA-88123456781234567812345678
1000 WATTS
MAX TOTAL
Set Shunting Pins To Engage AC With Zone Or Source Numbers 1-8
120-240 VAC
50-60 Hz
QUAD AC CONTROLLER
ACC-48
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION!
RISQUE DE CHOC ELECTRIQUE.
NE PAS OUVRIR
MADE IN U.S.A.
1. Delta-88 9 Pin "D" programmed for source AC control. - Set one shunting
pin per AC outlet according to source inputs. Set 3 pins for MT-3000.
2. Delta-88 9 Pin "D" programmed for zone AC control. - Set one shunting
pen per AC outlet according to zone numbers. Set all shunting pins on
one AC Outlet for All-On source AC control when not using an ACC-3000.
3421
USED FOR SOURCES
1-4 AC SWITCHING
USED FOR SOURCES
5-8 AC SWITCHING
SET DELTA-88
9 PIN D TO
SOURCE TRACKING
(SEE PROGRAMMING 
DELTA-88)
MODIFIED
DELTA-88
9 PIN D
FOR ZONE
TRACKING
FOR AMP ON ZONE 2
DELTA-88 USING ACC-48s FOR SOURCE AC
SWITCHING & ACC-48 FOR ZONE AC SWITCHING
SET ACC-48 JUMPER PINS SUCH THAT SOURCE ONE HAS A JUMPER ONLY
ACROSS PIN 1, SOURCE 2 HAS JUMPER ON ONLY PIN 2, ETC.
THE ACC-48s FOUR AC OUTLETS CAN
BE USED TO TRIGGER AMPS, DECODERS, ETC THAT
ARE ZONE SPECIFIC. THESE COMPONENTS WILL ENGAGE ONLY
WHEN THAT ZONE TURNS ON. USE THE JUMPER PINS TO TURN
ON AN AC OUTLET FOR A ZONE BY PLACING THE JUMPER ON THE
CORRESPONDING ZONE NUMBER. WARNING ACC-48 10 AMP MAX.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ada Delta-88 and is the answer not in the manual?

Ada Delta-88 Specifications

General IconGeneral
BrandAda
ModelDelta-88
CategoryStereo System
LanguageEnglish

Related product manuals