High efficient scroll on anti-vibration mounts, acti-
vated by a 2-pole electric motor with internal heat
protection. They are supplied, as standard, with an
electric heater resistance, powered automatically
when the unit stops as long as the unit is power on.
Made with copper pipes and aluminium louvered
fins blocked by mechanical expansion of the pipes,
equipped with protection grid.
Unit with heat plate, insulated externally
with closed cell material to reduce heat loss.
Positioned at compressor inlet to protect from
refrigerant return.
evaporator, depending on the heat load, in order to
Mechanical dehydrator filter realised in ceramics
and hygroscopic material, able to withhold impuri
-
ties and any traces of humidity present in the cool-
ing circuit.
Used to check the refrigerant gas load and any pres-
ence of humidity in the cooling circuit.
-
cycles.
Used to keep the refrigerant gas in the liquid state
when the machine accumulates it excessively during
functioning.
Made in hot galvanised sheet steel with suitable
thickness and painted with polyester powders able
electric fans are protected electrically by magnet-
metal grids, according to the IEC EN 60335-2-40
Standard.
Equipped with steel filtering mesh; prevents the
heat exchangers from clogging.
It checks that there is circulation of water.If
this is not the case, it blocks the unit
Set at 6 bar and the discharge conveyor, discharging
the excess pressure occurs in the event of abnormal
pressures
assembled on the upper part of the hydraulic sy-
stem; it releases any air bubbles that may be present
in the system.
Positioned above evaporator, it has the task of
controlling that there is water circulation.
Adversary, it blocks the unit.
Calibrated at 6 BAR and with piped discharger,
dischargers if abnormal pressure occurs.
mesh with holes that do not exceed one millimetre.
It is indispensable in order to prevent serious damage
to the plate exchanger.
With nitrogen pre-load membrane
pressure drops
In stainless steel, with a 100-litre capacity. In
order to reduce the thermal dispersion and
-
of a suitable thickness.
Allows discharge of water
WATER FEATURES
PH 6-8
less than 200 mV/cm
less than 50 ppm
less than 50 ppm
less than 0.3 ppm
less than 50 ppm
less than 50 ppm
none
none
less than 30 ppm
With fixed calibration, placed on high pressure side
of cooling circuit, inhibits functioning of compressor
if abnormal work pressure occurs.
Placed on low pressure side of cooling circuit, signals
the work pressure to control board, generating a pre-
warning in case abnormal pressure occurs.