- 3 -
Scientific Instruments Manufacturer GmbH
D-46149 Oberhausen • +49-208-94 10 78-0 • www.sim-gmbh.de
CONTENT
1 PARAMETER MENU OF THE CONTROLLER (FIRMWARE V1.10) .......................... 4
2 DIP INSTALLATION PROCEDURE ............................................................................ 5
2.1 Replacing the ion source ........................................................................................... 5
2.2 Installing the DIP on the Agilent 5975 MSD ............................................................... 5
2.3 Installing the DIP on the Agilent 7000 Triple Q ........................................................... 7
2.4 Connecting the DIP and the GC ................................................................................. 8
2.5 Configuration of the DIP-Controller ............................................................................ 9
2.6 Installing the DIP Software ......................................................................................... 9
2.7 Insert the ChemStation/MassHunter methods for the DIP .........................................10
2.7.1 5975 MSD: ChemStation methods .........................................................................10
2.7.2 7000 Triple Q MS/MS: MassHunter methods .........................................................10
2.8 Adjustment of the CombiPAL to the MS-DIP System (optional) ................................10
2.9 Push rod performance test ........................................................................................10
2.10 Tuning of the DIP-MS System ...................................................................................10
2.10.1 Autotune 5975 MSD with DIP .................................................................................10
2.10.2 Autotune 7000 TripleQ MS/MS with DIP .................................................................11
2.11 Controller: Update of the firmware ............................................................................11
3 EXACT POSITIONING OF THE PUSH ROD IN THE ION SOURCE .........................12
4 TEMPERATURE CALIBRATION OF THE CONTROLLER ........................................14
4.1 Menu: General Configuration ....................................................................................14
4.2 Temperature Calibration ...........................................................................................14
5 DIP TEST PROCEDURES ........................................................................................16
5.1 DIP Temperature accuracy test ................................................................................16
5.2 Leak test ...................................................................................................................17
5.3 Coupling test: CombiPAL with MSD-DIP and GC (optional, for DIP - 45° type with
5975 MSD) ...........................................................................................................................18
5.4 DIP (EI) Performance test .........................................................................................19
5.5 DIP (PCI) Performance test for DIP/5975 MSD Systems ..........................................22
APPENDIX ...........................................................................................................................24