- 3 -
Scientific Instruments Manufacturer GmbH
D-46149 Oberhausen +49-208-94 10 78-0 www.sim-gmbh.de
CONTENT
1 PARAMETER MENU OF THE CONTROLLER (FIRMWARE V1.10) .......................... 4
2 DIP INSTALLATION PROCEDURE ............................................................................ 5
2.1 Replacing the ion source ........................................................................................... 5
2.2 Installing the DIP on the Agilent 5975 MSD ............................................................... 5
2.3 Installing the DIP on the Agilent 7000 Triple Q ........................................................... 7
2.4 Connecting the DIP and the GC ................................................................................. 8
2.5 Configuration of the DIP-Controller ............................................................................ 9
2.6 Installing the DIP Software ......................................................................................... 9
2.7 Insert the ChemStation/MassHunter methods for the DIP .........................................10
2.7.1 5975 MSD: ChemStation methods .........................................................................10
2.7.2 7000 Triple Q MS/MS: MassHunter methods .........................................................10
2.8 Adjustment of the CombiPAL to the MS-DIP System (optional) ................................10
2.9 Push rod performance test ........................................................................................10
2.10 Tuning of the DIP-MS System ...................................................................................10
2.10.1 Autotune 5975 MSD with DIP .................................................................................10
2.10.2 Autotune 7000 TripleQ MS/MS with DIP .................................................................11
2.11 Controller: Update of the firmware ............................................................................11
3 EXACT POSITIONING OF THE PUSH ROD IN THE ION SOURCE .........................12
4 TEMPERATURE CALIBRATION OF THE CONTROLLER ........................................14
4.1 Menu: General Configuration ....................................................................................14
4.2 Temperature Calibration ...........................................................................................14
5 DIP TEST PROCEDURES ........................................................................................16
5.1 DIP Temperature accuracy test ................................................................................16
5.2 Leak test ...................................................................................................................17
5.3 Coupling test: CombiPAL with MSD-DIP and GC (optional, for DIP - 45° type with
5975 MSD) ...........................................................................................................................18
5.4 DIP (EI) Performance test .........................................................................................19
5.5 DIP (PCI) Performance test for DIP/5975 MSD Systems ..........................................22
APPENDIX ...........................................................................................................................24

Other manuals for Agilent Technologies 5975 MSD

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 5975 MSD and is the answer not in the manual?

Agilent Technologies 5975 MSD Specifications

General IconGeneral
BrandAgilent Technologies
Model5975 MSD
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals