Order online at www.agilent.com/chem/store
Inlets
Extended temperature range, lowest bleed.
Maximum injection port temperature 400°C.
Plasma coating eliminates sticking in the injection port.
Pre-conditioned; ready to use.
Blister packaging for cleanliness and convenience.
Ideal for use with low-bleed, "Mass Spec" capillary columns.
Bleed and Temperature Optimized Septa (BTO)
Description Unit Part No.
11 mm septa 50/pk 5183-4757
11 mm septa 100/pk 5183-4757-100
5 mm septa through-hole for on-column, in glass jar 50/pk 5183-4758
Comparison of Coring, With and Without CenterGuide (30x magnification)
Major coring before 100 autoinjections
High-Temperature Septa without CenterGuide
Agilent BTO Septa with CenterGuide
V
ery little coring even after 700 autoinjections
B
TO septa, 5183-4757
Bleed and Temperature Optimized Septa (BTO)
Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies gc/ms series and is the answer not in the manual?

Agilent Technologies gc/ms series Specifications

General IconGeneral
Dynamic Range10^6
Mass Range1050 amu
Mass ResolutionUnit mass resolution
Scan SpeedUp to 12, 500 amu/sec
Ionization ModeElectron Ionization (EI), Chemical Ionization (CI)
Temperature RangeUp to 350°C
Vacuum SystemTurbomolecular Pump
Data SystemAgilent MassHunter

Summary

Gas Management

Gas Purification Systems

Overview of purifiers for removing oxygen, moisture, and hydrocarbons to achieve proper gas purity.

Sample Introduction

Syringe Troubleshooting Guide

Guidance on common syringe problems like bent plungers or needles and their solutions.

Inlets

Split/Splitless Inlets

Overview of the popular split/splitless inlet and troubleshooting common issues like peak broadening.

Cool On-Column Inlets

Advantages of cool on-column injection, sample considerations, and troubleshooting tips.

Programmed Temperature Vaporizer (PTV) Inlets

Benefits, practices, and rationales for PTV inlets, offering flexibility in sample introduction.

Detectors

Flame Ionization Detector (FID)

Routine maintenance, typical problems, and troubleshooting for the FID.

Electron Capture Detector (ECD)

Liner selection, makeup gas adapter maintenance, thermal cleaning, and leak testing for ECD.

Thermal Conductivity Detector (TCD)

Filament maintenance, lifetime extension, cell contamination, and solvent flush procedures for TCD.

Flame Photometric Detector (FPD)

Recommended gas flows, maintenance, contamination, and ignition problems for the FPD.

GC/MS Systems

Maintaining Mass Selective Detectors (MSD)

Benefits of maintaining GC/MSD systems, including reduced downtime and longer lifespan.

MSD Contamination

Identifying contamination sources in the GC and MSD, and common contaminants and their origins.