EasyManua.ls Logo

Agilent Technologies G1888

Agilent Technologies G1888
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Agilent Technologies
Agilent G1888 Network
Headspace Sampler
User Information
medium_standard.book Page 1 Tuesday, February 17, 2004 10:14 AM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies G1888 and is the answer not in the manual?

Agilent Technologies G1888 Specifications

General IconGeneral
TypeHeadspace Sampler
ModelG1888
ManufacturerAgilent Technologies
CategoryLaboratory Equipment
Carrier GasHelium, Nitrogen
Power Requirements100–240 VAC, 50–60 Hz

Summary

Notices and Safety Information

Safety Notices

Crucial safety warnings and cautions for instrument operation and potential hazards.

Manual Overview and Chapter Summaries

Introduction

Purpose, intended reader, and conventions of the manual.

Introduction to Headspace and the G1888 Sampler

Headspace theory, instrument overview, and operational principles.

The Keypad and Controls

Explains keypad layout, navigation, accessing functions, and editing setpoints.

Advanced Functions and Configuration

Details non-routine functions, system settings, and calibration procedures.

Sample Preparation and Method Entry

Steps for sample prep, loading trays, and creating/managing analysis methods.

Developing and Running Methods

Discusses parameters like oven temp, event times, and matrix effects to optimize analysis.

Instrument Maintenance Procedures

Outlines maintenance schedules, parts replacement, and alignment checks.

Troubleshooting and Error Resolution

Guides for diagnosing and fixing common issues and error messages.

Keypad Navigation and Method Management

Keypad Navigation and Functions

Explains keypad layout, navigation, accessing functions, and editing setpoints.

Method Management Keys

Details functions of Active Method and Menu keys for parameter control.

Advanced Functions and System Configuration

Using Advanced Functions

Guide to accessing and utilizing various advanced functions for instrument setup.

System Configuration Settings

Covers Zone Calibration, LAN/RS232 configuration, and MAC address.

Sample Preparation and Method Entry

Sample Preparation

Steps for preparing sample vials, including filling, sealing, and loading.

Entering and Managing Methods

Procedures for creating, storing, loading, and chaining analysis methods.

Method Development and Sample Running

Method Development Strategies

Discusses parameters like oven temp, event times, and matrix effects to optimize analysis.

Running Sample Analysis

Steps for setting conditions and executing sample analysis runs.

Instrument Maintenance Procedures

Maintenance Schedule and Parts

Recommended maintenance activities and list of common replacement parts.

Component Replacement and Alignment

Guides for replacing parts like loop cover, probe, loop, tubing, and checking alignments.

Leak Testing and Calibration

Procedures for leak testing and zone calibration to ensure instrument integrity.

Troubleshooting and Error Resolution

Chromatographic and Vial Handling Issues

Troubleshooting for peak issues, poor reproducibility, and vial handling errors.

System and Communication Problems

Resolving issues with heated zones, pressures, communication, and system errors.

Related product manuals