Agilent Technologies 1260 Infinity G1315C - User Manual

Agilent Technologies 1260 Infinity G1315C
314 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Agilent Technologies
Agilent 1260 Infinity
Diode Array and Multiple
Wavelength Detector
User Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 1260 Infinity G1315C and is the answer not in the manual?

Agilent Technologies 1260 Infinity G1315C Specifications

General IconGeneral
TypeDiode Array Detector (DAD)
Max Pressure400 bar
Wavelength Range190-950 nm
Detector TypeDiode Array Detector
Light SourceDeuterium and tungsten lamps
Data Acquisition RateUp to 80 Hz
Path Length10 mm
Cell Volume13 µL
Flow Cell Volume13 µL
Flow Cell Path Length10 mm
Weight12 kg
Flow Rate RangeUp to 10 mL/min
Bandwidth1 nm
Diode Resolution1 nm
Drift< 1 x 10^-3 AU/h
Spectral Bandwidth1 nm
Operating PressureUp to 400 bar
Operating Temperature4°C to 55°C

Summary

Introduction

Introduction to the Detector

Provides an overview of the detector and its key features.

Site Requirements and Specifications

Site Requirements

Outlines environmental and power considerations for instrument installation.

Performance Specifications

Lists key performance metrics such as detection type, data rate, and wavelength range.

Installing the Module

Installing the Detector

Step-by-step guide for installing the detector module into the system.

Using the Detector

Setting up an Analysis

Explains how to prepare the system and configure an analysis.

How to optimize the Detector

Optimizing for Sensitivity, Selectivity, Linearity and Dispersion

Details methods to optimize key analytical parameters for best results.

Error Information

What Are Error Messages

Explains how error messages are displayed and their general meaning.

Detector Error Messages

Details error messages specific to the detector module.

Test Functions

Self-test

Describes the automated self-test procedure and its individual tests.

Wavelength Verification and Calibration

Provides instructions for verifying and calibrating the detector's wavelength accuracy.

Maintenance

Cautions and Warnings

Highlights safety precautions to be observed during maintenance procedures.

LAN Configuration

TCP;IP parameter configuration

Details the required TCP/IP settings for network operation.

Initialization mode selection

Explains how to select network initialization modes like Bootp or DHCP.

Appendix

Safety Information

Provides general safety precautions for operating and maintaining the instrument.

Related product manuals