57
Order online at www.agilent.com/chem/store
Inlets
Agilent MS Certified Liners
Agilent MS Certified Split and Splitless Liners are manufactured and tested to our highest
level of scrutiny to assure reproducibility.
We have built years of experience into the MS Certified Liners to provide the quality
and consistency needed for critical applications, especially those using esterification
agents for trace level analysis such as toxicology or drugs of abuse applications.
Geometrical dimensions and tolerances of the glass are controlled by Statistical Process
Control (SPC) with 100% Go-No-Go check.
Glass wool is pre-qualified with mass spectrometry, then inserted using a unique
manufacturing procedure to improve reproducibility.
Deactivated MS Certified Liners are treated with Agilent's proven proprietary deactivation
process developed to last longer than other commercially available treatment.
Random samples of MS Certified Liners are tested using both FID and MSD analysis of
challenging probes to evaluate Acid/Base deactivation, response linearity, peak
symmetry, and bleed and background noise.
Each Agilent MS Certified Liner is traceable by the lot codes silk screened on the liner.
Agilent Single Taper Split Liners are made to strict dimension specifications for optimal
inlet performance and feature the tightest tolerances for OD, ID, taper, and glass wool
placement. For ease of use and reproducibility, the liners have a positioning bead,
a restriction to secure the position of the glass wool, and a feature to consistently
self-position to the recommended height. The liners also feature Agilent's
proprietary deactivation.
Agilent recommends part number 5183-4647 as the top split liner choice for
:
Highest run-to-run area reproducibility
Least discrimination for wide boiling point range samples
Useable with widest range of conditions and sample types
Easy self-adjusting installation
Agilent Split Liners
NEW!
MS certified split liner, 5188-6576

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies gc/ms series and is the answer not in the manual?

Agilent Technologies gc/ms series Specifications

General IconGeneral
BrandAgilent Technologies
Modelgc/ms series
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals