MIL-STD-1553 Reference Manual
Appendix A – Document/Software History
General or S/W Function
Change
Updated the lla, llb, and llc parameters for
ApiCmdBiuIntrCheck to reflect the ul_Lla, ul_Llb, and
ul_Llc values for the parameters used in the
ApiInstIntHandler function.
Added documentation that this function utilizes Driver Cmd
“0x0034”.
Modified inst parameter to indicate that the BC wait
instruction is not allowed for acyclic minor frames.
Modified xid parameter to indicated that interrupts can be
enabled/disabled for the skip instruction.
Clarified sxh parameter definition
Corrected names for parameter smod, values 2 and 3.
Corrected global documentation errors
Added detailed return code description for functions
Changed description for parameter ‘instr’
Changed description for parameter ‘xid’
Extended send mode capability to send at a pre-defined time
Changed description for parameter ‘xid’
Corrected type of parameter ‘cnt’, was different
between prototype and parameter description
Corrected description for “buffer header”
Changed description for parameter ‘hid’
Renamed modes Standard Tagging Mode – to Function
mode and EFABus mode to Tagging Mode
Changed description for parameter ‘min’
Changed description for parameter ‘bc_hid’
Changed description for parameter ‘instr’
ApiCmdBCIni
ApiCmdBCInstrTblGetAddrFrom
Label
ApiCmdBCInstrTblGen
ApiCmdBCInstrTblIni
ApiCmdBCXferDef
Clarified descriptions of function/parameters.
Added note to indicate that delay instructions are not allowed
for acyclic instruction table definitions.
ApiCmdBCInstrTblGetAddrFrom
Label
Function changed
added parameter ‘saddr’
extended description for parameter ‘smod’
Clarified which modes were applicable to Standard Framing