Airwell Multi Split DUO 50 DCI - User Manual

Airwell Multi Split DUO 50 DCI
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Multi Split DUO 50 DCI
Indoor Units Outdoor Units
FLO 9 DCI
DUO 50 DCI
FLO 12 DCI
K 9 DCI
K 12 DCI
SX 9 DCI
SX 12 DCI
BS 12 DCI
SEPTEMBER –– 2008
REFRIGERANT
R410A
HEAT PUMP
SM DUODCI 1-A.1 GB
CONTENT

Questions and Answers

  • S
    Samuel MillerAug 2, 2025
    Why is my Airwell Multi Split DUO 50 DCI compressor running but not cooling?
    • J
      Jason PattonAug 2, 2025
      If your Airwell Air Conditioner's compressor is running, but the unit isn't cooling, the Electronic Expansion Valve (EEV) might be stuck in the closed position. You should check the EEV.
  • Y
    Yvonne StewartAug 9, 2025
    What to do if one Airwell Air Conditioner indoor unit is not cooling and the other is leaking?
    • J
      Jamie LeeAug 10, 2025
      If one Airwell Air Conditioner indoor unit is operating in cool mode but has no cooling capacity, while the other unit has water leaks or freezing problems, the communication wires between the two indoor units may be switched. Check and correct the communication wire connections.
  • K
    Kelsey BrownAug 16, 2025
    What to do if the Airwell Multi Split DUO 50 DCI Air Conditioner indoor fan won't start?
    • J
      Julie DouglasAug 16, 2025
      If the indoor fan of your Airwell Air Conditioner doesn't start, but the louvers are open and the green LED is lit, here are a few things to check: * If the unit is in heat mode, the coil may not be warm yet. Try switching to cool mode. * The outdoor unit might be in the opposite mode. Change the operation mode and see if the fan starts. * There may be a problem with the PCB or capacitor. Set the fan to high speed and check the power supply to the motor. For Triac controlled motors, it should be higher than 130VAC; for fixed speed motors, it should be higher than 220VAC. If the power supply is OK, replace the capacitor. If not, replace the controller.
  • D
    Diana Copeland MDAug 25, 2025
    How to fix an Airwell Air Conditioner when the power indicator is off?
    • B
      Bruce HarrisAug 26, 2025
      If the power supply indicator (Red LED) on your Airwell Air Conditioner indoor unit isn't lit, it indicates a power supply problem. Check the power supply from the outdoor unit. If the power supply is OK, then check the display and display wiring. If the display and wiring are OK, replace the controller.

Summary

Product Data Sheet

Rating Conditions

Performance Data

FLO 9 DCI Performance Details

Cooling and heating capacity, and correction factors for FLO 9 DCI.

FLO 12 DCI Performance Details

Cooling and heating capacity, and correction factors for FLO 12 DCI.

K 9 DCI Performance Details

Cooling and heating capacity, and correction factors for K 9 DCI.

K 12 DCI Performance Details

Cooling and heating capacity, and correction factors for K 12 DCI.

SX 9 DCI Performance Details

Cooling and heating capacity, and correction factors for SX 9 DCI.

SX 12 DCI Performance Details

Cooling and heating capacity, and correction factors for SX 12 DCI.

BS 12 DCI Performance Details

Cooling and heating capacity, and correction factors for BS 12 DCI.

Pressure Curves

Electrical Data

Wiring Diagrams

Refrigeration Diagrams

Tubing Connections

Control System

Compressor Frequency Control

Details NLOAD setting, target frequency, and compressor starting control.

Mode Operations and Protections

Details operation in Cool, Heat, Auto, Dry modes and system protection mechanisms.

Troubleshooting

System Failures and Corrective Actions

Lists common system failures, probable causes, and corrective actions.