11-7
CONTROL SYSTEM
SM DUODCI 1-A.1 GB
11.17.3 Compressor over Heating Protection
Compressor temperature can be in one of 5 control zones (4 in protection, and 1 normal), t.
Control Status
Compressor Temperature
Increases
EBSe
P1 Norm SR
P2 D1 SR
P3 D2 D1
Stop Compressor SC
11.17.4 Compressor over Current Protection
Normal
P1
P2
Stop-Compresor
CTTOH1
CTTOH2
CTTOH3
CTTOH4
CTT
P3
Normal
Stop-Rise
HzDown1
HzDown2
Stop-Compresor
CCROC1
CCROC2
CCROC3
CCROC4
CCR