EasyManuals Logo

AJAX Hub User Manual

AJAX Hub
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
The tests do not start immediately but within a period of 36 seconds when using default settings. The test time start
depends on the settings of the detector ping interval (the “Jeweller” menu in the hub settings).
Jeweller Signal Strength Test
Detection Zone Test
Attenuation test
According to the requirements of EN50131, the level of the radio signal sent by wireless devices is reduced during
the test mode.
Choosing an installation place
Before installing the detector, conduct the Jeweller signal strength test.
Install MotionProtect Outdoor at the height of 0.8 1.3 m, ensuring the upper lens axis to be parallel to the ground,
and the supposed intrusion path is perpendicular to the lens axis.
MotionProtect Outdoor sends an alarm to the hub only if both PIR sensors detect identical motion. The difference in
time of motion detection should not exceed 1.5 seconds.