Socket Operating Principle
Socket turns on/off 230 V power supply according to the scenarios or at user command via the Ajax Security System
application.
Socket is furnished with a protection system against voltage variation beyond the range of 184 253 V or over-
current protection above 11А. In this case, power supply is interrupted, resuming after normalization of the voltage
and current values.
Maximum resistive load 2.5 kW. In the case of inductive or capacitive loads, the maximum current is reduced to 8 A at 230 V AC!
You may view the consumed power of the electrical appliances connected via Socket through the application. There
is a consumed electricity meter.
Under insignificant loads (below 25 W), inaccurate current and power consumption readings may be displayed due to hardware limitations.