Installation of the Relay
The relay should be only installed by a qualified electrician! Regardless of the type of the electrical circuit in which the device is installed.
Communication range with the hub absent any obstacles between the devices up to 1,000 meters. Take account of
this when choosing the location for Relay.
If the device has a low or unstable signal strength, use a radio signal range extender ReX.
1. De-energize the cable to which Relay will be connected.
2. Connect the power supply cable to the Relay terminals, and then the Relay contact terminals to the required circuit
with wires/cable of a sufficient cross-section. It’s recommended to use cables with cross-section of 1.5 2 mm
2
.
3. If the device is installed in a connection box, install the antenna outside. The further the antenna is located away
from metal structures, the less the chance of radio signal shielding. The antenna must not be shortened under any
circumstances.
During the Relay installation and operation, follow the general electrical safety rules for using electrical devices, as well as the requirements of the
electrical safety regulations. It is expressly prohibited to disassemble the device.
Do not install the Relay:
1. Outside the premises (outdoors).
2. In metal junction boxes and electric service panels.