A01 Access Control Admin Guide
AKUVOX SMART INTERCOM www.akuvox.com
Wiegand Input Data Order:set the Wiegand input data sequence between
Normal and Reversed if you select Reversed then the input card number
will be reversed an vice versa.
Wiegand Output Data Order: set the Wiegand output data sequence
between Normal and Reversed if you select Reversed then the input card
number will be reversed an vice versa.
Wiegand Output CRC Enable: tick to enable the parity check function to
ensure that signal-based data can be transmitted correctly according to
the established data transmission format.
19.2. Integration via HTTP API
HTTP API is designed to achieve an network-based integration between the
third party device with the Akuvox intercom device. You can configure the
HTTP API function on the web Services > HTTP API interface for the
integration.
Parameter set-up:
HTTP API: select “Enable” or “ Disable “ to enable or disable the HPTT
API function for the third party integration. For example, if the function is
disabled any request to initiate the integration will be denied and be
returned HTTP 403 forbidden status.
Auth Mode: select among four options: “None” “ WhiteList” “ Basic”,
“ Digest” for authorization type, which will be explained in detail in the
following chart.