Albin Pump ALH Instruction Manual Albinpump.com albinpump@irco.com 27
since 1928
9 | CHARACTERISTICS AND TECHNICAL SPECIFICATIONS
9.1 - PERFORMANCE CURVES
ALH
Characteristics / Technical Specications
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
10 bar (145 psi)
5 bar (72 psi)
15 bar (220 psi)
7.5 bar (110 psi)
Continuous 24/24h
ALH40
Intermittent* Occasional*
3 Bars
8 Bars
10 bar (145 psi)
7.5 bar (110 psi)
5 bar (72 psi)
15 bar (220 psi)
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Continuous 24/24h
ALH32
Intermittent* Occasional*
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
10 bar (145 psi)
7.5 bar (110 psi)
5 bar (72 psi)
15 bar (220 psi)
Continuous 24/24h
ALHX40
Intermittent* Occasional*
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
10 bar (145 psi)
7.5 bar (110 psi)
15 bar (220 psi)
5 bar (72 psi)
Continuous 24/24h
ALH50
Intermittent* Occasional*
Pump speed: (Rpm)
Flow: m
3
/h (gpm)
1 rpm = 0.038 m
3
/h = 0.1651 gpm
1 rev = 0.6250 L = 0.1651 gal
10
0.38
(1.7)
20
0.75
(3.3)
30
1.13
(4.9)
40
1.50
(6.6)
50
1.88
(8.3)
60
2.25
(9.9)
70
2.63
(11.6)
80
3.0
(13.2)
90
3.38
(14.9)
100
3.75
(16.5)
110
4.13
(18.2)
120
4.50
(19.8)
130
4.88
(21.5)
140
5.25
(23.1)
Pump speed: (Rpm)
Flow: m
3
/h (gpm)
Pump speed: (Rpm)
Flow: m
3
/h (gpm)
1 rpm = 0.059 m3/h = 0.2576 gpm
1 rev = 0.9750 L = 0.2576 gal
10
0.59
(2.6)
20
1.17
(5.1)
30
1.75
(7.7)
40
2.34
(10.3)
50
2.92
(12.8)
60
3.51
(15.4)
70
4.10
(18)
80
4.68
(20.6)
90
5.27
(23.2)
100
5.85
(25.7)
110
6.44
(28.3)
120
7.02
(30.9)
130
7.61
(33.5)
140
8.19
(36)
Pump speed: (Rpm)
Flow: m
3
/h (gpm)
1 rpm = 0.080 m
3
/h = 0.3522 gpm
1 rev = 1.3333 L = 0.3522 gal
10
0.8
(3.5)
20
1.6
(7)
30
2.4
(10.6)
40
3.2
(14)
50
4
(17.6)
60
4.8
(21.1)
70
5.6
(24.6)
80
6.4
(28.2)
90
7.2
(31.7)
100
8
(35.2)
110
8.8
(38.7)
120
9.6
(42.3)
1 rpm = 0.175 m
3
/h = 0.7705 gpm
1 rev = 2.9167 L = 0.7705 gal
10
1.75
(7.7)
20
3.5
(15.4)
30
5.25
(23.1)
40
7
(30.2)
50
8.75
(38.2)
60
10.5
(46.3)
70
12.25
(53.3)
80
14
(61.4)
90
15.75
(69.4)
Temperature °C (°F)
Temperature °C (°F)
1.5 (2)
3 (4)
1.1 (1.5)
2.2 (3)
2.2 (3)
4 (5)
Installed power kW (HP)Installed power kW (HP)
Installed power kW (HP)Installed power kW (HP)
1.5 (2)
5.5 (7.5)
2.2 (3)
7.5 (10)
1.1 (1.5)
4 (5)
Temperature °C (°F)Temperature °C (°F)
*Intermittent use : minimum one hour stop aer 2 hours run / * Occasional use : maximum one hour a day
Pump speed: (Rpm)
Flow: l/h (gpm)
Temperature °C (°F)
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
10 bar (145 psi)
7.5 bar (110 psi)
5 bar (72 psi)
15 bar (220 psi)
Continuous 24/24h
ALH25
Intermittent* Occasional*
3 bar (44 psi)
8 bar (116 psi)
10 bar (145 psi)
40°C (104°F)
50°C (122°F)
60°C (140°F)
70°C (158°F)
80°C (176°F)
Continuous 24/24h
ALH20
Intermittent* Occasional*
0.37 (0.50)
0.25 (0.33)
0.55 (0.75)
Installed power kW (HP)
Installed power kW (HP)
1 rpm = 8.50 L/h = 2.245 gph
1 rev = 0.1417 L = 0.0374 gal
10
85
(22.5)
20
170
(44.9)
30
255
(67.4)
40
340
(89.8)
50
425
(112.3)
60
510
(134.7)
70
595
(157.2)
80
680
(179.6)
90
765
(202.1)
100
850
(224.5)
110
935
(247)
120
1020
(269.5)
Pump speed: (Rpm)
Flow: m
3
/h (gpm)
1 rpm = 0.016 m
3
/h = 0.070 gpm
1 rev = 0.2667 L = 0.0704 gal
10
0.16
(0.7)
20
0.32
(1.4)
30
0.48
(2.1)
40
0.64
(2.8)
50
0.80
(3.5)
60
0.96
(4.2)
70
1.12
(4.9)
80
1.28
(5.6)
90
1.44
(6.3)
100
1.60
(7)
110
1.76
(7.7)
120
1.92
(8.4)
130
2.08
(9.1)
140
2.24
(9.8)
1.5 (2)
2.2 (3)
1.1 (1.5)
Temperature °C (°F)