User Manual
Product information and planning
9500 MPR Rel. 3.1
3DB18809AAAA Issue 1 141/980
Table 28. Waveguide Flange Data
2.8.4.4  ODU Coupler
The ODU coupler is used in the 1+1 HSB or 1+1/2x(1+0) FD co-polar configurations.
The coupler can be equal type (3 dB/3 dB insertion loss) or unequal type (1.5 dB on the main path/6 dB 
on the secondary path).
The couplers are connected between the cabinets and the antenna.
Freq 
Band 
Radio 
Flange
Waveguide 
Mating 
Flange
Waveguide 
Type
Spring 
Washers 
Reqd
Bolts 
Reqd
Bolt 
Type
Thread 
Spec
Hole 
Depth 
mm
Bolt Length 
Required
6 GHz  UDR70  PDR70  WR137  8 x M5  8  M5x0.8  6H  10  Flange  thickness  + 
Hole depth - 2mm
7/8 GHz  UDR84  PDR84  WR112  8 x M4  8  M4x0.7  6H  8  Flange  thickness  + 
Hole depth - 2mm
10/11 GHz  UDR100  PDR100  WR90  8 x M4  8  M4x0.7  6H  8  Flange  thickness  + 
Hole depth - 2mm
13 GHz  UBR120  PBR120  WR75  4 x M4  4  M4x0.7  6H  8  Flange  thickness  + 
Hole depth - 2mm
15 GHz  UBR140  PBR140  WR62  4 x M4  4  M4x0.7  6H  8  Flange  thickness  + 
Hole depth - 2mm
18/23/26 
GHz 
UBR220  PBR220  WR42  4 x M3  4  M3x0.5  6H  6  Flange  thickness  + 
Hole depth - 2mm
28/32/38 
GHz
UBR320  PBR320  WR28  4 x M3  4  M3x0.5  6H  6  Flange  thickness  + 
Hole depth - 2mm