2.6 Environmental and Electrical Characteristics
– System Parameters (par. 2.6.1)
– ODU300 (par. 2.6.2)
– MPT-HC/MPT-HC V2 (par. 2.6.3)
– MPT-MC (par. 2.6.4)
– Radio performances (par. 2.6.5)
– General characteristics (Power Injector) (par. 2.6.6)
– General characteristics (Power Extractor) (par. 2.6.7)
2.6.1 System Parameters
General with ODU300
Operating Frequency Range 6 - 38 GHz
Max Ethernet throuput from 10 up to 310 Mbit/s
Modulation Options in FCM 4 QAM, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Adaptive Modulation 4 QAM, 16 QAM, 64 QAM,
General with MPT-HC/MPT-HC V2
Operating Frequency Range 6 - 38 GHz
Max Ethernet throuput 340 Mbit/s
Bandwidth up to 56 MHz
Modulation Options in FCM 4 QAM, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Adaptive Modulation 4 QAM, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
General with MPT-MC
Operating Frequency Range 6 - 38 GHz
Max Ethernet throuput 155 Mbit/s
Bandwidth up to 28 MHz
Modulation Options in FCM 4 QAM, 16 QAM, 32 QAM, 64 QAM, 128 QAM
Adaptive Modulation 4 QAM, 16 QAM, 32 QAM, 64 QAM, 128 QAM
Radio Path Protection Options
Non Protected, 1+0
Protected Hot Standby, 1+1
Space Diversity, 1+1
Frequency Diversity, 1+1
XPIC 1+0/1+1 (with MPT-HC V2)
Radio LAG with four radio channels (with MPT-HC/MPT-HC V2/MPT-MC)