EasyManua.ls Logo

Alcatel-Lucent 9500 MPR - Figure 66. 7;8 Ghz MPT-HC Architecture

Alcatel-Lucent 9500 MPR
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual
Product information and planning
9500 MPR Rel. 3.1
3DB18809AAAA Issue 1 147/980
In 1+1, switch of the recovered clock between the local and the one coming from second MPT-HC
depending on the traditional RPS position
Deframing of the Rx modem frame
Re-assembly of fragmented Ethernet frame
Decompression of TDMoEth frames header
Extraction of MPT-HC to MPT-HC messages needed for radio link (ATPC, ACM, ...)
Management of service channels frames
Switch of the management frames from internal processor to user port.
Management of the 1+1 EPS protection layer 2 messages
Send the recovered clock to the MSS
In 1+1 EPS, transmit or not the Ethernet frames to the MSS depending on the EPS position
2.8.5.1.2 RF Section
There are two architectures, the difference between these two architectures are only on Rx side:
For the first one (used in MPT-HC band 7/8 GHz) there are only two frequency conversions between
RF input frequency and base band frequency
For the second one (used for all other MPT-HC bands) there are three frequency conversions
The block diagrams of these two architectures are shown hereafter.
Figure 66. 7/8 GHz MPT-HC architecture