MSS Power supply
Input voltage range -40.5 to -57.6 Vdc The input voltage range can be
also from -57 to -60 Vdc without
any damage, but with no guar
-
anteed performance
+19 Vdc to +36 Vdc The optional +24 Vdc/-48 Vdc
converter module has to be
installed for +24 Vdc office
applications
Standards Compliance
EMC MSS-8/MSS-4 EN 301 489-1, EN 301 489-4
EN 55022 Class B)
Operation ODU300/MPT ETS 300 019, Class 4.1
Operation MSS-8/MSS-4 ETS 300 019, Class 3.2
Storage ETS 300 019, Class 1.2
Transportation ETS 300 019, Class 2.3
Safety IEC 60950-1/EN 60950-1
Radio Frequency EN 302 217 Classes 2, 4 & E5
Water Ingress ODU300/MPT IEC 60529 (IPX6)
Environmental
Operating Temperature
MSS-8/MSS-4 Guaranteed -5° to +55° C
ODU300/MPT Guaranteed -33° to +55° C
Start up temperature from low
temperature
ODU300 -20°C
MPT -40°C
Humidity
MSS-8/MSS-4 Guaranteed 0 to 95%, non-condensing
ODU300/MPT Guaranteed 0 to 100%
Management
Protocol SNMP
Interface, electrical Ethernet 10/100/1000 Base-T (RJ45)
Local/remote Configuration and
Support Tool
JUSM
Routing Protocols supported Static routing and dynamic routing (OSPF)
TMN In-band 2 interfaces
Network Management Alcatel-Lucent 1350 OMS
Alcatel-Lucent 1352 Compact
Alcatel-Lucent 5620 SAM