EasyManuals Logo

Alcatel-Lucent OmniPCX Office Installation Manual

Alcatel-Lucent OmniPCX Office
230 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
T2 Name T1 Name Function
BUSY BUSY B-channels busy (red LED lights up if at least 1 B-channel is busy)
RAI (ATD) RAI Remote frame alarm (red LED lights up on alarm)
AIS (SIA2M) AIS Too many "1's in the 2-Mbit binary train (red LED lights up on alarm)
NOS (MS) NSIG Absence of 2-Mbit signal (red LED lights up on alarm)
CRC (TE) CRC CRC error (red LED lights up on alarm)
LOS (PVT) NSYN Loss of frame alignment (red LED lights up on alarm)
2.4.2.8 APA Boards
This board is used to connect to the analog public network (2, 4 or 8 LR).
The APA board does not support pulse dialing in Australia and New Zealand.
2.4.2.9 LAN-X Boards
These boards are used to create a local area network (LAN) by connecting client PCs,
IP-Phones, an external Lanswitch and servers.
"# !$%  $
       
2-11

Table of Contents

Other manuals for Alcatel-Lucent OmniPCX Office

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Office and is the answer not in the manual?

Alcatel-Lucent OmniPCX Office Specifications

General IconGeneral
VoIP ProtocolsSIP, H.323
Power Supply100-240 VAC, 50/60 Hz
Humidity10% to 90% non-condensing
TypeIP PBX
Maximum TrunksUp to 60
Voice codecsG.711, G.729
Network Interfaces10/100 Ethernet
WeightVaries depending on the model/configuration