The Reset window opens.
3. Select Reboot and click OK.
4. In the confirmation window, click Yes.
Displaying SIP Connection Current Status
As of R9.0, this feature allows the display of SIP connection status.
To display SIP connection status:
1. In OMC, go to Users/Base stations List > Details.
2. Read the SIP connection status (under the terminal's physical status).
The following table lists the different displayed status.
Displayed Status Meaning
Set not connected SIP phone disconnected from network / No
SIP registration request from the phone
SIP registration KO SIP registration request from SIP Phone
rejected by Alcatel-Lucent OmniPCX Office
Communication Server
Set unregistered SIP phone unregistered from Alcatel-Lucent
OmniPCX Office Communication Server
SIP registration OK SIP phone connected and successfully
registered to Alcatel-Lucent OmniPCX Office
Communication Server
4.4.2.1.3 Video Call parameters
The Alcatel-Lucent OmniPCX Management Console is used to enable the video call support
for the 8082 My IC Phone sets. Once configured it is possible to make:
- Basic P2P video calls between 8082 My IC Phone (VHE-2) and any SIP phone with video
support.
- Basic video calls from 8082 My IC Phone (VHE-2) over a SIP trunk
The configuration for video is carried out in two steps:
1. Generic SIP phone parameters for video calls are verified and modified if necessary, see
Generic video parameters
2. Each set is enabled, see Enabling video support for a 8082 My IC Phone set
Generic video parameters
The parameters in the table are generic (common) to all 8082 My IC Phone sets. They are
accessed from:
OMC -> Subscribers Misc -> Generic Parameters for SIP Phones -> Video Call
parameters
Video Camera Country Frequency: defines the vertical scan frequency which is needed to
avoid flickering of video. This is same as the mains power frequency of the country. Default
value for this parameter is kept based on the target type (country) of the OmniPCX Office.
Chapter
4
  ()
4-46
       

Table of Contents

Other manuals for Alcatel-Lucent OmniPCX Office

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent OmniPCX Office and is the answer not in the manual?

Alcatel-Lucent OmniPCX Office Specifications

General IconGeneral
VoIP ProtocolsSIP, H.323
Power Supply100-240 VAC, 50/60 Hz
Humidity10% to 90% non-condensing
TypeIP PBX
Maximum TrunksUp to 60
Voice codecsG.711, G.729
Network Interfaces10/100 Ethernet
WeightVaries depending on the model/configuration

Related product manuals