43
If LOOP is turned off after the BRC has reached the Loop End point
and has begun rewinding to the Loop Start point, the transport
will continue rewinding, without stopping at the Loop Start
point.
4.2A Setting Loop Points
To set the Loop Start and End points:
1. Press the EDIT button (the EDIT button LED will go on to indicate
you are in Edit mode);
2. Press the LOOP button;
The display will show the Loop Start point:
St
X
X "LocNamxx"
aa:bb:cc:dd
…where XX is one of the stored locate numbers (01–20; 21 is auto-
punch in, 22 is auto-punch out), LocNamxx is the cue name, and
aa:bb:cc:dd its corresponding tape address. The locate number and
address can be edited, but not the locate point’s name. The address is
displayed according to the type of Display Type you have selected. If in
NORMAL mode, the display will read 00:00:00
(minutes:seconds:frames) and the frames will default to 30 frames per
second. If in SMPTE mode, the display will read 00:00:00:00
(hours:minutes:seconds:frames); if in BARS mode, the display will
read 01–01/00 (bars:beats:sub-beats).
3. Use the UP/DOWN buttons to select a locate number between 1
and 22. The name and address will be updated as you scroll
through the stored locate points;
4. To display the Loop End point, press the LOOP button again;
The display will show:
En
Y
Y "LocNamyy"
ww:xx:yy:zz
5. Use the UP/DOWN buttons to select a locate number between 1
and 22. The name and address will be updated as you scroll
through the stored locate points. Just as when setting the Loop
Start point, only the locate number can be edited;