8138 SIP Multicolor Strobe Light
Advanced Settings Tab – Advanced Multicast
The default prepopulated multicast addresses above will work in most cases and should
only be altered for rare cases.
RTCP Port Selection
Select the port on which RTCP packets will be sent or received. If using the 'Next Higher
Port' option, ensure that the default multicast zone definitions are modified such that
zones are only assigned to even-numbered ports, leaving the next higher odd-numbered
ports free for RTCP packets.
Zone Definition
The “Expanded” Slave or Master zones can be enabled/disabled in Basic Settings >
Multicast. Default IP addresses and ports may be revised for any given zone in the table.
Important: Ensure that the Address and Port settings are the same for all master
and slave devices.
Strobe Pattern
When the 8138 Strobe Light is the multicast Slave, a strobe pattern will flash each time a
multicast stream is detected.
By default, the same flash pattern can be set for all Slave zones in the Basic Settings >
Features tab. Unique flash patterns may be revised on a per-zone basis in the table
above. For instance, emergency pages can be different on certain Slave strobes.