EasyManua.ls Logo

Allen-Bradley 1734-SSI - Work with the Conversion Dialog

Allen-Bradley 1734-SSI
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40 Rockwell Automation Publication 1734-UM007E-EN-P - October 2015
Appendix A Configure Modules in RSLogix 5000 Software
Work with the Conversion
Dialog
Follow these procedures to complete entries for the Conversion dialog.
1. From the General dialog, click Conversion to display the Conversion
dialog.
2. From the Conversion dialog, complete entries, referring to the table.
3. From the Conversion dialog, complete one of these.
Click OK to save changes and close the dialog.
or
Click Cancel to return to default values.
or
Click Apply to save changes you made on any of the dialogs and
continue to display the dialog, noting that you enable the Apply button
when you make changes to any of the dialogs.
or
Click another tab at the top of dialog.
For more information on these parameters, refer to the definitions in Chapter 4
of this publication.
For Select Comments
Gray-to-Binary Convert Click the checkbox Default is no Gray-to-binary convert with the checkbox
not checked.
Standardization Click the checkbox Default is no standardization with the checkbox not
checked.
Trailing Bits 0...16 When you check Standardization, Trailing Bits is
selectable.
Default is 0.
Sensor Resolution 1...65535 Default is 1.
Sensor Cycles 1...65535 Default is 1.

Related product manuals