Rockwell Automation Publication 20A-UM001N-EN-P - July 2013 57
Programming and Parameters Chapter 1
UTILITY (file E)
Diagnostics
228 [Status 2 @ Fault]
Captures and displays [Drive Status 2] bit pattern at the
time of the last fault.
Read Only
210
224
230
229 [Alarm 1 @ Fault]
Captures and displays [Drive Alarm 1] at the time of the last
fault.
Read Only
211
224
230
230 [Alarm 2 @ Fault]
Captures and displays [Drive Alarm 2] at the time of the last
fault.
Read Only
212
224
230
File E
Group
No.
Parameter Name and Description
See page 14 for symbol descriptions
Values
Related
00000000000000xx
10 01234567891112131415
1 = Condition True
0 = Condition False
x = Reserved
Bit #
Ready
Active
Running
Jogging
Stopping
DC Braking
AutoTuning
DB Active *
AutoRst Ctdn
AutoRst Act
Curr Limit
Bus Freq Reg
Motor Overld
DPI at 500 k
Nibble 1Nibble 2Nibble 3Nibble 4
* Enhanced Control Option Only.
000000x00000000x
10 01234567891112131415
1=Condition True
0=Condition False
x =Reserved
Bit #
Prechrg Actv
UnderVoltage
Power Loss
Str At PwrUp
Anlg in Loss
IntDBRes OH
Drv OL Lvl 1
Drv OL LVl 2
Decel Inhibt
Waking
(2)
Motor Therm
(1)
In PhaseLoss
(2)
Load Loss
(2)
Ground Warn
(2)
Nibble 1Nibble 2Nibble 3Nibble 4
(1)
Enhanced firmware 1.001 & later.
(2)
Enhanced firmware 2.001 & later.
000000000000000x
10 01234567891112131415
1 = Condition True
0 = Condition False
x = Reserved
Bit #
DigIn CflctA
DigIn CflctB
DigIn CflctC
Bipolr Cflct
MtrTyp Cflct
NP Hz Cflct
MaxFrq Cflct
VHz NegSlope
IR Vlts Rang
FlxAmps Rang
SpdRef Cflct
Ixo Volt Rang
(2)
Sleep Config
(2)
TB Ref Cflct
(1)
PTC Conflict
(1)
Nibble 1Nibble 2Nibble 3Nibble 4
x0xxxxxxxxxxxxxx
26 161718192021222324252728293031
1 = Condition True
0 = Condition False
x = Reserved
Bit #
UserSetCflct
(2)
Nibble 1Nibble 2Nibble 3Nibble 4
(1)
Enhanced firmware 1.001 & later.
(2)
Enhanced firmware 2.001 & later.

Other manuals for Allen-Bradley PowerFlex 70

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 70 and is the answer not in the manual?

Allen-Bradley PowerFlex 70 Specifications

General IconGeneral
Input Voltage200-240V AC, 380-480V AC, 500-600V AC
Frequency Range0 - 400 Hz
Humidity5% to 95% non-condensing
Output Voltage0 to Input Voltage
Control MethodsSensorless Vector Control
CommunicationsEthernet/IP, DeviceNet, ControlNet
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Ground Fault
Operating Temperature0°C to 50°C (32°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Enclosure RatingIP20, NEMA Type 1

Related product manuals