132 Rockwell Automation Publication 1783-UM007G-EN-P - February 2017
Chapter 5 Install Stratix 5700 Switches
Parts List and Required Tools
Verify that you have these items.
The PoE connector ships only with switch models with PoE ports. The
connector is required only if you plan to use PoE.
If needed, an SD card can be ordered separately from the switch.
Obtain these tools:
Ratcheting torque screwdriver that exerts up to 1.69 N
m (15 inlbs) of
pressure
Small, flat-blade screwdriver
#6 ring terminal lug for 5.3 mm
(10 AWG) wire, such as Thomas &
Bett part number 10RC6 or equivalent
Crimping tool, such as Thomas & Bett part number WT2000,
ERG-2001, or equivalent
5.3 mm
2
(10 AWG) copper ground wire, such as Belden part number
9912 or equivalent
Wire-stripping tool
For panel-mounting without a DIN rail, M5 or #10-24 or #10-32 bolts
or screws with 1.27 cm (0.5 in.) O.D. flat washers
1 Stratix® 5700 switch
2 Documentation
3 PoE connector
4 SD card
At the end of its life, this equipment should be collected separately from any
unsorted municipal waste.
1
2
3
4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley Stratix 5400 and is the answer not in the manual?

Allen-Bradley Stratix 5400 Specifications

General IconGeneral
ModelStratix 5400
CategoryIndustrial Ethernet Switch
LayerLayer 2/3
ManagementWeb-based, CLI, SNMP
ManagedYes
Port Types10/100/1000 Mbps Ethernet
Power over Ethernet (PoE)Yes
Operating Temperature-40°C to 70°C (-40°F to 158°F)
MountingDIN Rail
ProtocolsEtherNet/IP
Security FeaturesIEEE 802.1X
Power SupplyAC or DC
RedundancyRSTP
Input Voltage24 VDC or 100-240 VAC