Rockwell Automation Publication 1783-UM007G-EN-P - February 2017 163
Install Stratix 8000 and 8300 Switches Chapter 6
Obtain these tools:
Ratcheting torque screwdriver that exerts up to 1.69 N
m (15 inlbs) of
pressure
#6 ring terminal lug for 5.3 mm
(10 AWG) wire, such as Thomas &
Bett part number 10RC6 or equivalent
Crimping tool, such as Thomas & Bett part number WT2000,
ERG-2001, or equivalent
5.3 mm
2
(10 AWG) copper ground wire, such as Belden part number
9912 or equivalent
Wire-stripping tool
For panel-mounting without a DIN rail, M5 or #10-24 or #10-32 bolts
or screws with 1.27 cm (0.5 in.) O.D. flat washers
For simplified cabling, the automatic medium-dependent interface crossover
(auto-MDIX) feature is enabled by default on the switch. With auto-MDIX
enabled, the switch detects the required cable type for copper Ethernet
connections and configures the interfaces accordingly. Therefore, you can use
either a crossover or a straight-through cable for connections to a 10/100 or 1
0/100/1000 Ethernet switch port, regardless of the type of device on the other
end of the connection.

Table of Contents