28 Rockwell Automation Publication 1783-UM001B-EN-P - May 2010
Chapter 2 Network Services Setup
When you send email with MSG instructions, the length of the LEN field
must be added to the string length, as shown in the program example.
3. Open tags and click the Edit tab.
4. Insert EMS_EMAIL and EmailDstStr.
Both tags are of the type EmailString. These tags can be created later when
the MSG instruction is inserted. The text of the email does not have to be
static. You can program a controller project to collect specific data to be
sent in an email. For more information on using ladder logic to manipulate
string data, see the Logix5000 Controllers Common Procedures
Programming Manual, publication 1756-PM001
.
5. Create a tag of the type MESSAGE; our example uses a tag named
SendEmail_EDM.
EMS_Email