Chapter 15: MAC Address Table
218
Modify Static Unicast Address
To modify the port assignment of a unicast MAC address in the MAC
address table, perform the following procedure:
1. From the main menu on the left side of the page, select the Bridge
folder.
2. From the Bridge folder, select Static Unicast.
The Static Unicast Address Table Page is displayed. See Figure 81 on
page 216.
3. Select Modify next to the static MAC address that you want to change.
The Modify Static Unicast Address Page is displayed (not shown
here).
4. In the Group Member row, select the check boxes for the ports that
you want to include or remove in the Group Member area. Selected
ports are indicated with a check mark.
Note
To restore the original group member ports, click Restore.
5. Click Apply.
6. From the main menu on the left side of the page, select Save
Configuration to Flash to permanently save your changes.

Table of Contents

Other manuals for Allied Telesis AT-GS950/8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-GS950/8 and is the answer not in the manual?

Allied Telesis AT-GS950/8 Specifications

General IconGeneral
Ports8 x 10/100/1000BASE-T
Switching Capacity16 Gbps
Forwarding Rate11.9 Mpps
MAC Address Table Size8K
Power SupplyInternal AC power supply
Operating Temperature0°C to 40°C (32°F to 104°F)
Uplink Ports2 x 1000BASE-X SFP
Jumbo Frame Support9K bytes
Dimensions440 x 44 mm
Storage Temperature-40 to 70 °C
Humidity10% to 90% non-condensing

Related product manuals