EasyManua.ls Logo

Allied Telesis XS900MX Series - Verifying the Member Switch; Table 11: Verifying the Member Switch

Allied Telesis XS900MX Series
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XS900MX Series Installation Guide for VCStack
123
Verifying the
Member Switch
Perform the steps in Table 11 to confirm the configuration of the member
switch.
12 Designate the ports as the trunk with the STACKPORT command.
awplus(config-if)# stackport
% Save the config and restart the system for this change to take
effect.
Steps 13 to 18 save your changes and reboot the switch.
13 Return to the Global Configuration mode.
awplus(config-if)# exit
14 Return to the Privileged Exec mode.
awplus(config)# exit
15
Save your changes with the WRITE command.
awplus# write
Building configuration ...
[OK]
16 Restart the switch.
awplus# reboot
reboot system? (y/n):
17 Type “Y” for yes.
18 Wait two minutes for the switch to initialize its management software.
19 Go to “Verifying the Member Switch,” next.
Table 10. Configuring the Member Switch - Part II (Continued)
Step Description and Command
Table 11. Verifying the Member Switch
Step Description and Command
1 Start a local management session. Refer to “Starting a Local Management Session” on
page 86.
2 Move to the Privileged Exec mode.
awplus> enable

Table of Contents