Installation
Support--frame assembly
L31--113EN/01
4/6
06--2003
E ALSTOM
Prep aring the colu mn
Dismantling the case
of the poles
Remove the strenghtening beams of the case and free the support legs of the
frame.
Remove the side panels of the case.
Preparing the pole
D Sling the pole with the aid of two flexible lifting straps (1).
D Extract the pole from the case and put it down on the case wood cover lay-
ing :
-- f i r s t
, the interrupting--chamber extremity (4) on a wood wedge,
-- second
, the upper part of the housing (10) on a wood wedge to ensure the
correct installing of the frame supports.
X
minimum
= 260 mm
X
1
1
4
10