OPERATION
Del uxe Control C ook & Ho l d Opera tors Manual MN- 4 6708 Re v 1 11/20
82
How to Calibrate the Temperature Probe
Before you begin Make sure:
The oven is on, but not in cooking or holding mode.
You have a thermometer.
You have a container filled with ice and water.
Procedure To calibrate the probe, do the following.
Step Action
1. Place the probe and the thermometer in a container of ice water and allow
the temperature to settle to 32°F (0°C).
2. Touch the menu icon a. The control displays the menu screen.
3. Touch the Settings icon b. The control displays the General Settings screen.
Continued on next page
Action needed
1
2
1