E-31 8 - Control Board Control board too warm 1. Make sure cooling fan(s) are operating.
2. Make sure exhaust vents are clean and free
of debris.
3. Make sure oven clearances are met.
4. Ambient temperature greater than 105°F
(41°C).
5. Check the door gasket for damage and
proper seal.
E-31 9 - Interface Board Interface board too warm 1. Make sure cooling fan(s) are operating.
2. Make sure exhaust vents are clean and free
of debris.
3. Make sure oven clearances are met.
4. Ambient temperature greater than 105°F
(41°C).
5. Check the door gasket for damage and
proper seal.
E-55 56 - Vent valve Vent (upper) not open 1. Power down control using on/off icon.
2. Cycle power to the oven either by
unplugging the unit or by turning the main
power switch off and then back on.
3. Resume use of oven. If error reappears
contact a service provider.
E-55 56 - Vent valve Lower vent valve not open 1. Power down control using on/off icon.
2. Cycle power to the oven either by
unplugging the unit or by turning the main
power switch off and then back on.
3. Resume use of oven. If error reappears
contact a service provider.
E-62 2 - Convection fan Motor VFD (upper) over current 1. Power down control using on/off icon.
2. Cycle power to the oven either by
unplugging the unit or by turning the main
power switch off and then back on.
3. Resume use of oven. If error reappears
contact a service provider.
E-62 2 - Convection fan Lower motor VFD over current 1. Power down control using on/off icon.
2. Cycle power to the oven either by
unplugging the unit or by turning the main
power switch off and then back on.
3. Resume use of oven. If error reappears
contact a service provider.
E-66 2 - Convection fan VFD (upper) error 1. Power down control using on/off icon.
2. Cycle power to the oven either by
unplugging the unit or by turning the main
power switch off and then back on.
3. Resume use of oven. If error reappears
contact a service provider.
E-66 2 - Convection fan Lower VFD error 1. Power down control using on/off icon.
2. Cycle power to the oven either by
unplugging the unit or by turning the main
power switch off and then back on.
3. Resume use of oven. If error reappears
contact a service provider.
Code Component Description Troubleshooting steps