Structure and function
14
AMALOG BAH0017.1 11.08
4.1.2 Operation with pneumatic seed drills
The
• monitors the tramline control in the distributor head.
Acoustic alarm in event of incorrect slider position.
• monitors the blower fan speed.
If the actual speed deviates by more than 10%
from the target speed, an acoustic signal is initi-
ated and in the display the control lamp (Fig. 4
1)
above the speed symbol (Fig. 4/2) flashes.
The speed monitoring is only active when the
seed drill is working.
Fig. 4
4.1.3 Operation with DMC Primera direct seed drills
The
• initiates an alarm when the set minimum fertiliser quantity is rea-
ched in the fertiliser hopper.
4.2 Rotary cultivator operation
The
• monitors the function of the overload clutch.
Acoustic alarm in event of tool carrier standstill.