U10C034 Telephony Version v1.4 June 2008
36
a full scan on the spectrum after the T4 timeout before dropping
the line voltage. The Private MIB feature will drop the line voltage
as soon as there is a T4 timeout.
• The PacketCable MIBs provide control on whether line voltage should
be maintained if MTA fails provisioning. The Private MIBs do not.
• The PacketCable MIBs provide control on the reset timer value for
CM reset and MTA reset. The Private MIBs do not.
PacketCable
Policy
PacketCable Timers emtaMaintenanceControlMask emtaMaintenance Timers
Policy 1 None OnCmReset(0),
OnRFLoss(1),
OnMtaReset(2),
OnCMSLoss(3)
None
Policy 2 None OnCmReset(0),
OnMtaReset(2),
OnCMSLoss(3)
emtaMaintenanceRF-
DisconnectTimeout
Policy 3 pktcEnNcsEndPntLVMgmtMaintTimer Not Required emtaMaintenanceWindowBegin,
emtaMaintenanceWindowDuration,
emtaMaintenance
QuarantineTimeout,
emtaMaintenance
DisconnectTimeout,
emtaMaintenance
RFDisconnectTimeout
Policy 4 None Not Required None required.
N/A N/A Any other bit settings Any combination of the
emtaMaintenanceWindow-Begin,
emtaMaintenanceWindow-Duration,
and the Timeout MIB settings.
2.2.7 Configuring Stuck Service-Flow Cleanup Control