Universal IV - Level Measurement System
20
3.3 Standards and Approvals
3.3.1 FM US Approvals - Install per 420-0004-412-CD
TheUniversalIVLevelTransmitterisratedasIntrinsicallySafe
forClassI,IIandIll,GroupsA-GandClassI,Zone0,Group
IIC,inaccordancewithdrawing420-0004-412-CD;Nonincendive
ClassI,Division2,GroupsA-DHazardous(Classified)Locations.
Furthermore,theIntegralversionisratedasExplosionprooffor
ClassI,Division1,GroupsC&D;DustlgnitionproofforClass
II&Ill,Division1,GroupsE-GandClassI,Zone1,GrouplIB
Hazardous(Classified)Locationswithanintegralsensorthat
isIntrinsicallySafeforClassI,II&Ill,GroupsA-GandClass
I,Zone1Hazardous(Classified)Locations.TheRemoteversion
isratedasExplosionproofClassI,Division1,GroupsC&D;
Dust-lgnitionproofforClassII&Ill,Division1,GroupsE-G
andClassI,Zone1,GrouplIBHazardous(Classified)Locations
withconnectionstoa700SeriessensorthatisIntrinsicallySafe
forClassI,II&Ill,GroupsA-GandClassI,Zone1Hazardous
(Classified)Locations.
3.3.2 FM Canada Approvals - Install per 420-0004-412-CD
TheUniversalIVLevelTransmitterisratedasIntrinsically
SafeforClassI,IIandIll,GroupsA-GandClassI,Zone
0,GroupIIC,inaccordancewithdrawing420-0004-412-CD;
NonincendiveClassI,Division2,GroupsA-DHazardous
Locations.
Furthermore,theIntegralversionisratedasExplosionproof
forClassI,Division1,GroupsC&D;Dustlgnitionprooffor
ClassII&Ill,Division1,GroupsE-GandClassI,Zone1,
GrouplIBHazardousLocationswithanintegralsensorthatis
IntrinsicallySafeforClassI,II&Ill,GroupsA-GandClass
I,Zone1HazardousLocations.TheRemoteversionisrated
asExplosionproofClassI,Division1,GroupsC&D;Dust-
lgnitionproofforClassII&Ill,Division1,GroupsE-GandClass
I,Zone1,GrouplIBHazardousLocationswithconnectionstoa
700SeriessensorthatisIntrinsicallySafeforClassI,II&Ill,
GroupsA-GandClassI,Zone1HazardousLocations.