MFC 1000, 1 m x 1 m MFC 1000.1, 1 m x 1 m
1, (single turn) 1, (single turn)
8/20 s pulse current up to 2.000 A 8/20 s pulse current up to 2.000 A
50/60 Hz AC current 50/60 Hz AC current
continuous 250 A/m continuous 250 A/m
short time for 3 s 1.200 A short time for 3 s 1.200 A
Safety laboratory plugs 4mm M14 screws
continuous ac currents up to 32A/ plug
3.2kA (8/20s pulse current)
High current plugs
continuous ac current > 30A to 250A cont. ac current > 30A to 250A
short time currents 3 s up to 1500A short time currents 3s up to 1500A
Double stand for MFC 1000 coil with base Height adjustable and coil 360
on casters with brakes; rotation mechanism degrees rotatable; double stand
with 3 position brakes.
turntable for horizontal and vertical fields turntable for horizontal and
vertical fields
Aluminium, 4cm² cross section Aluminium, 4cm² cross section
variac NX1-260-16, 0-260 V/16 A
variac NX1-280-16, 0-280 V/16 A
VAR 3005A-S16, 0-260 V/16 A
Manual variac 0-260 V, 5 A ( for magnetic fields up to 100 A)
Line voltage variac NX1-2x0-16
230V 16A (for H-field 1.000 A/m: max. 39A for 3s)
Current transformer (30 A/m)
5,50 kg Transformer
0,35 kg 4 Safety labor cables 2m
Current transformer (1.000 A/m)
Output current (Transformator)
0 250 A rms continuous transformator secondary
max. 1.200 A for 3 s (approx. 600 A for 115 V line power)
200 A rms continuous (cable connection MFT 100 MFC 1000.x with 50mm²)
male: Multicontact KST 14AR-N/50 200 A cont, 3 kA 3s
female: Multicontact KBT 14AR-N/50 200 A cont, 3 kA 3s
26,45 kg Transformer
2,0 kg Cable 2 units
0,25 kg Mains cable
using a compact NX5/NX7, NSG 30x0A
Single pulse, max. repetition rate 10 s
100...2.000 A (multiplied with antenna factor)
8/20 s current pulse as per IEC 1000-4-5