AXB-F117 Stealth 1 Camera Controller AXCESS Programming 29
Configuration commands (Cont.)
Command Function
'ZOOM PRESET=POS' Set the Zoom voltage output to recall positional presets
(default). This is applicable only if the ZOOM SIGNAL=S
command is in effect, and the ZOOM switch is set to the
S position (servomotor mode).
'ZOOM PRESET=SPEED' Set the Zoom voltage output to recall speed presets. This
is applicable only if the ZOOM SIGNAL=S command is in
effect, and the ZOOM switch is set to the S position
(servomotor mode).
'ZOOM SIGNAL=S' Set the Zoom output to be a servomotor output. This
setting corresponds to the S position (servomotor mode)
setting on the ZOOM switch.
'ZOOM SIGNAL=M' Set the Zoom output to be a motor output. This setting
corresponds to the M position (motor mode) setting on the
ZOOM switch.
'FOCUS PRESET=POS' Set the Focus voltage output to recall positional presets
(default). This is applicable only if the FOCUS SIGNAL=S
command is in effect, and the FOCUS switch is set to the
S position (servomotor mode).
'FOCUS PRESET = SPEED' Set the FOCUS voltage output to recall speed presets.
This is applicable only if the FOCUS SIGNAL=S command
is in effect, and the FOCUS switch is set to the S position
(servomotor mode).
'FOCUS SIGNAL = S' Set the Focus output to be a servomotor output. This
setting corresponds to the FOCUS switch in the S
position.
'FOCUS SIGNAL = M' Set the Focus output to be a motor output. This setting
corresponds to the M position (motor mode) setting on the
FOCUS switch.
'READ ALL' Force the device to read and update levels to the Central
Controller.
'ZAP!' Initialize all memory to default settings. This includes
speed settings, deviation settings, configuration settings,
and all presets.