38 AXCESS Programming AXB-F117 Stealth 1 Camera Controller
Preset parameters and commands
Figure 41 lists preset parameters and Figure 42 lists the preset commands.
Preset parameters
Preset: 1 - 255
TIME: (Optional) If specified, 0 to 255 in tenth seconds. If not specified, at current rate.
Used for voltage outputs. Used only for recall preset.
SPEED: (Optional) 0 to 127. 0 is slowest and 127 if fastest. If not specified, at current speed.
Used for Motor Drive outputs, including pan/tilt control. Used for Recall
Preset only.
Preset commands
Command Description
'CP<preset 1-255>’ Clear a preset from memory.
Examples:
SEND_COMMAND CAM,'CP1'
Clears Preset 1.
SEND_COMMAND CAM,’CP100’
Clears Preset 100.
'PRESET TIMER=time' Set preset timer. The preset timer is the length of
time after a preset is reached that the unit monitors
the preset. If the AXB-F117 overshoots within the
preset time, it will re-activate the preset recall. Time
values are in tenths of a second. A 0 setting
disables the preset timer function. The default
setting is 5.
time = 0-100.
Example:
SEND_COMMAND CAM,'PRESET TIMER=10'
Sets preset timer to 1 second.
Figure 41
Preset parameters
Figure 42
Preset commands