EasyManuals Logo
Home>AMX>Controller>AXB-F117 Stealth 1

AMX AXB-F117 Stealth 1 User Manual

AMX AXB-F117 Stealth 1
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #43 background imageLoading...
Page #43 background image
AXB-F117 Stealth 1 Camera Controller AXCESS Programming 39
Preset commands (Cont.)
Command Description
'RP<preset 1-255>[T<time 0-
255 in tenth
seconds>][S<speed 0-
127>][I<- or +>]'
Recall a stored preset. Optional parameters include
ramp time for servomotor positional presets, motor
mode, servomotor speed mode, and inclusion
(+ default) or exclusion (-) of iris in preset.
Examples:
SEND_COMMAND CAM,'RP1'
Recalls preset 1. Same as turning on channel 101.
If any are in servomotor positional mode, the
current voltages for zoom, focus, and/or iris will be
ramped to the preset voltages at the current speed.
If any are in servomotor speed mode, the motor
drive outputs for zoom and/or focus outputs will run
at their preset-defined speeds until the preset
positions are reached on the POTs. Regardless of
the preset type used, the pan/tilt drives will run at
their current speeds until the proper positions are
reached on their POTs. Channel 101 is turned on.
SEND_COMMAND CAM,'RP1I-'
Recalls preset 1. Same as turning on channel 101.
If any are in servomotor positional mode, the
current voltages for zoom, and /or focus iris will be
ramped to the preset voltages at the current speed.
If any are in speed mode, the motor drive outputs
for zoom and/or focus outputs will run at their
preset-defined speeds until the preset positions are
reached on the POTs.
Regardless of the preset type used, the pan/tilt
drives will run at their current speeds until the
proper positions are reached on their POTs.
Channel 101 is turned on.
The iris signal will be excluded from the preset recall
and will not be included in displaying feedback as to
whether the preset has been completed.
SEND_COMMAND CAM,'RP10T100'
Recalls preset 10. If any are in positional mode,
voltage outputs for zoom, focus, and/or iris will ramp
to position in 10 seconds. If any are in speed mode,
the motor drive outputs for zoom and/or focus
outputs will run at their preset-defined speeds until
the preset positions are reached on the POTs.
Pan/tilt outputs will use current speed. Turns on
channel 110.