EasyManua.ls Logo

AMX MVP-5100 - Panel Information Page

AMX MVP-5100
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup Pages
47
MVP-5100/5150 5.2" Modero Viewpoint Touch Panels
Panel Information Page
The Panel Information page provides detailed panel information (FIG. 40).
Features on this page include:
FIG. 40 Panel Information page
Panel Information Page
Back: Saves all changes and returns to the previous page.
WiFi/Wired/USB Icon: The icon to the left of the Connection Status Icon displays whether the current
connection to the Master is
Wireless (image of a radio antenna), Wired (image
of three networked computers), or
USB (USB connection symbol).
Connection Status icon: The icon in the upper-right corner of each Setup page provides a constant
visual indication of current connection status.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx
Master.
Panel Type: Displays the model of the panel being used.
Firmware Version: Displays the version number of the G4 firmware loaded on the panel.
Setup Port: Displays the setup port information (value) being used by the panel.
High Port: Displays the high port (port count) value for the panel.
High Address: Displays the high address (address count) value for the panel.
High Channel: Displays the high channel (channel count) value for the panel.
High Level: Displays the high level (level count) value being used by the panel.
Serial Number: Displays the specific serial number value assigned to the panel.
Setup Pages Version: Displays the type and version of the Setup pages being used by the panel.
Screen Width: Displays the screen width (in pixels). MVP-5100 = 640 pixels.
Screen Height: Displays the screen height (in pixels). MVP-5100 = 480 pixels.
Screen Refresh Rate: Displays the video refresh rate applied to the incoming video signal.
Screen Rotation: Displays the degree of rotation applied to the on-screen image.
Power Up Page: Displays the page assigned to display after the panel is powered-up.
Start Up String: Displays the start-up string.
Wake Up String: Displays the wake up string used after an activation from a timeout.
Sleep String: Displays the sleep string used during a panel’s sleep mode.
Stand By String: Displays the stand by string used during a panel’s Stand By mode.
Shutdown String: Displays the shutdown string used during a panel’s Shutdown mode.