A1 23 DTR.APC.APR.ALW.03
(ENG)
5.6. APC2000ALW/L. Measurement ranges and metrological parameters.
5.6.1. APC2000ALW/L…level transmitter. Measurement ranges.
N°
1
2 3
Nominal range (FSO) 0...20m H
2
O 0...10m H
2
O 0...2,5m H
2
O
Minimum set range 2m H
2
O 1m H
2
O 0,5m H
2
O
Possibility of zer shift 0...18m H
2
O 0...9m H
2
O 0...2m H
2
O
5.6.2. APC–2000ALW/L…level transmitter. Metrological parameters.
Accuracy ± 0,16% (FSO) for the APC-2000ALW nominal range
Long term stability
accuracy / 2 years
Error due to supply voltage changes ± 0,002%(FSO)/1V
Thermal error ± 0,1%(FSO)/10ºC
Ambient temperature -40…+80ºC
Medium temperature -40…+120ºC
5.6.3. APC–2000ALW/L…. level transmitter. Pressure Connectors
- SG-25 sensor,
- SG-25S sensor,
- SG-25C sensor,
- SG-25S-tytan sensor,
- SG-16 sensor,
5.6.4. APC–2000ALW/L…. pressure, level transmitter.
Pressure range see p. 5.2.1.
Metrological see p. 5.2.2.
Pressure connectors see p. 5.2.3.