48
Table 2 Inverter Mode Specifications
MODEL
8KW
Rated Output Power
8000W
Output Voltage Waveform
Pure Sine Wave
Output Voltage Regulation
230Vac± 5%
Output Frequency
60Hz or 50Hz
Peak Efficiency
93%
Overload Protection
100ms@≥205% load;5s@≥150% load; 10s@110%~150% load
Surge Capacity
2* rated power for 5 seconds
Low DC Warning Voltage
46.0Vdc
42.8Vdc
40.4Vdc
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
Low DC Warning Return Voltage
48.0Vdc
44.8Vdc
42.4Vdc
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
Low DC Cut-off Voltage
44.0Vdc
40.8Vdc
38.4Vdc
@ load < 20%
@ 20% ≤ load < 50%
@ load ≥ 50%
High DC Recovery Voltage
64Vdc
High DC Cut-off Voltage
66Vdc
DC Voltage Accuracy
+/-0.3V@ no load
THDV
<5% for linear load,<10% for non-linear load @ nominal voltage
DC Offset
100mV
No Load Power Consumption
<75W