INSTALLATION
/ 21
Warning
The exhaust gas ducts must not be in contact with or close
to inammable material and must not pass through building
structures or walls made of inammable material.
When replacing an old appliance, the ue system must be
changed.
Important
Ensure that the ue is not blocked.
Ensure that the ue is supported and assembled in accordance
with these instructions.
150 mm
118
* Min slope: 1˚
1˚= 17.5mm per metre
150 mm
* pente
Installation without extension
Installation with extension
Level
Level
slope
Fig. 3
118 mm
150 mm
Minimum Length = 500 mm
180 mm
Fig. 2